Its no secret that finned tubes are core components of heat exchangers. After the products initial conception nearly a century ago, they continue to be in high demand among buyers. Surely there must be a reason, right?
The company is the world’s best stainless steel heat exchanger tube supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.
Dura-G Embedded Finned Tube
The Beginnings of Efficiency
In , Edward G. Lehman had a vision: create an efficient way to increase the contact area with external fluid and improve heat transfer coefficients. The Pennsylvania-based inventor received his first patent in September , only to perfect his craft in April . Today, we can find finned tubes in industrial settings, office buildings, and even our own homes.
Finned tubes are typically manufactured using one of four metallic elements, each with their own unique advantages and a variety of applications.
Stainless steel: Ideal for corrosive conditions and/or a high temperature.
Carbon steel: Ideal for high temperature applications where corrosion is not an issue.
Aluminum: Ideal for a high heat transfer rate in Air Cooling applications.
Copper: Ideal for the most efficient high heat transfer rate with common metals.
Many finned tubes are also manufactured using alloys.
A Finned Tube Here, A Finned Tube There
From heated pools and hot tubs to industrial boilers, finned tubes are working their science. Some finned tubes offer multiple functions for increased productivity. In addition to providing hot water for residential and commercial consumers, industrial boilers serve the space heating needs of chilly tenants in apartment buildings, office buildings, and warehouses. Heated pools and hot tubs use hot water from a boiler to keep the chlorinated water at a cozy temperature. There you have it. Finned tubes are used in many ways that improve your life.
Finned Tubes Are Cool
Its no secret that the capabilities of a finned tube heat exchanger are enough to pique the interest of buyers. Dry cooling is increasing in popularity, primarily due to excess water usage in steam power plants. Many plants are implementing the use of air-cooled heat exchangers to cool the process steam.
Condensers are the hub of outdoor air conditioning units and refrigerators. Through the process of heat transfer, a high-pressure gas (refrigerant) converts to a liquid for effective cooling. Yeah, finned tubes are pretty cool.
Finned Tubes Save Money And Resources
The only alternative to a finned tube is a bare metal tube an inefficient, resource-depleting method that wreaks havoc among the wallets of consumers and plant operations. Along with the promotion of excess water usage in steam power plants, finless tubes cant take the heat literally. In comparison with finned tubes, the lack of surface area creates a relatively low range of temperatures.
A comparative analysis determined a finned tubes shell is lesser than that of a finless tube, ultimately saving sheet material and decreasing spending. If the higher cost of material isnt enough to deter buyers, finless tubes tend to have issues withstanding intense working conditions for prolonged periods of time. Bottom line: finned tube heat exchangers are more eco-friendly and durable.
Edward G. Lehmans design continues to prove its efficiency. At Energy Transfer, we believe in upholding his legacy by manufacturing only the most robust of finned tubes for optimal performance. Click here to request a quote, or give us a call at 330-868-. One of our representatives will be happy to assist.
Want to not screw up your finned tube project? Our FREE GUIDE tells you everything you need to know. Download yours today
Just like a car or a computer, a heat exchanger needs regular maintenance to keep running at peak performance. Fortunately, plate heat exchangers (PHE) are generally easier to maintain than other types of heat exchangers, and problems tend to be easier to diagnose.
In the absence of regularly scheduled maintenance, a PHEs efficiency naturally declines. The simple reason for this is plate fouling as matter builds up in the grooves of a plate, the heat transfer capacity of that plate diminishes (because the fouling is less thermally conductive than the plate itself). The more scaling there is on a plate, the faster it continues to foul, so its important to catch the issue early to avoid extended downtime and excessive maintenance costs.
While less likely, other parts of a plate heat exchanger can fail as well. Its important to visually inspect the gaskets, frame and bars whenever you open up the heat exchanger for any kind of maintenance. A habit of cursory visual examinations can save a lot of time and money in the long run.
If you want to learn more, please visit our website inconel 625 tubing.
Records
To ensure youre keeping your plate heat exchanger properly maintained, you should keep basic records. Those should include the make and model number, what kind of maintenance youve already performed and when you performed it, available spare parts in your inventory, and the number of plates and gaskets in the unit. You should also know the dimensions of the plate pack as specified by the manufacturer (PHEs arent tightened to a torque specification, but rather to the width of the plate pack) so you can periodically check it for tightness, and return it to its original state after scheduled maintenance. When you tighten the PHE, its also a good time to lubricate the carrying and guide bars to make opening the PHE easier next time.
Scheduled Maintenance
The most important kind of maintenance is the regular, scheduled maintenance that you do even if the unit appears to be working just fine. This is the equivalent of changing your cars oil before the Check Engine light comes on, or going to the dentist even if you dont have cavities (that is to say, you should do it!). Perform this kind of maintenance at least once every six months.
As mentioned above, regular visual examinations are important make sure the plate pack is tightened to specification, the carrying and guide bars are lubricated, and the gaskets appear undamaged. Then, check your pressure gauges at each end of the plate heat exchanger to make sure the pressure drop is within expected limits.
If, after the above regular maintenance tasks are performed, the pressure drop is excessive, then there is likely a fouling issue and youll have to do unscheduled maintenance, which means downtime. Its also possible that the problem lies somewhere else in your process. Make sure your pipes are in good shape, and all your pumps are doing their jobs. If everything else seems to be in working order, its time to clean your PHE. Request one of our service technicians to get your unit back up and running or perform preventative maintenance to minimize downtime.
Clean-In-Place
Periodic cleaning is the most effective form of maintenance and should comprise the bulk of your maintenance efforts. Most PHEs can be maintained with a clean-in-place (CIP) process, where you dont have to open the plate pack. The biggest goal of cleaning is to flush out the various kinds of debris that collect in a PHE over time, which will vary depending on your process.
To clean your plate heat exchanger, first drain both sides and isolate it from your system fluid (generally done with isolation valves). Then, flush water through both sides until it runs clear. For best results, you should flush the fluids counter to the direction that they run in operation. If a lot of debris comes out, then youre in good shape! If, however, the excessive pressure drop persists after putting the PHE back in service, or if you didnt see very much debris, then youll need something more aggressive than water.
The next step is to pass a cleaning agent through the PHE with a circular pump and a solution tank. The agent itself will be dictated by your particular process, but your PHE manufacturer can help you learn about the cleaning process in more detail if youre unsure. In particular, you must ensure that the cleaning agent is compatible with the plates and gaskets of your PHE. Chloride, for example, will almost surely corrode the plates if theyre made of stainless steel (which most are). After running the cleaning agent through your PHE, flush it with water again until both sides discharge clear. If, after putting the PHE back in service, it still runs under capacity, then youll need to open up the plate pack and clean it manually.
Manual Cleaning
To clean a plate heat exchanger manually, open the plate pack according to the manufacturers instructions. Its preferable to clean the plates without taking them out of the frame, which is one of the reasons why its recommended to install a PHE where there is plenty of space to maneuver around it.
Next, manually apply the cleaning agent to each plate to loosen any debris that may have accumulated. Then, rinse the agent off with a soft bristle brush and high-pressure washer. Wire brushes or metal pads are discouraged because they may score the plates. Be careful that you dont hit the gaskets with the washer directly, as the high pressure may loosen or dislodge them. After the plates are completely rinsed, reassemble the PHE and put it back into service everything should be good as new!
While this cleaning regimen is an involved process, it should still take no longer than 24 hours. Scheduled maintenance will take far less time, and will save your maintenance crew time and money.
More Resources
If youre reading this article because your plate heat exchanger has failed, you may find these articles helpful:
If youre not sure whether a plate heat exchanger is the right product for you, take a look at our Overview of Plate Heat Exchanger Technology.
Lastly, if you liked this article or found it helpful, please leave feedback or questions on social media.
If you are looking for more details, kindly visit astm a511 stainless steel hollow bar wholesale.